Welcome to the Ideal Logic Combi 35 manual‚ your comprehensive guide to installing‚ operating‚ and maintaining this high-efficiency combination boiler. This manual ensures safe and efficient use.
1.1 Overview of the Ideal Logic Combi 35 Boiler
The Ideal Logic Combi 35 is a high-efficiency‚ wall-mounted‚ condensing combination boiler designed for domestic use. It provides both central heating and instantaneous hot water‚ making it a versatile and space-saving solution. With outputs of 35kW‚ this boiler is suitable for medium-sized homes with higher hot water demands. Known for its reliability and energy efficiency‚ the Logic Combi 35 features a compact design‚ user-friendly controls‚ and advanced safety features. It operates on natural gas and is compatible with standard heating systems. This boiler is part of Ideal’s Logic series‚ renowned for its simplicity‚ efficiency‚ and cost-effectiveness‚ ensuring optimal performance while minimizing energy consumption.
1.2 Purpose of the Manual
This manual serves as a detailed guide for the installation‚ operation‚ and maintenance of the Ideal Logic Combi 35 boiler. It provides essential information for installers‚ users‚ and service engineers‚ ensuring safe and efficient use. The manual covers technical specifications‚ installation requirements‚ operating instructions‚ and troubleshooting tips. It also outlines safety precautions and best practices to maintain optimal boiler performance. By following the guidelines in this manual‚ users can ensure their boiler operates efficiently‚ reducing energy costs and extending its lifespan. The manual is a crucial resource for anyone involved with the boiler‚ promoting compliance with safety standards and manufacturer recommendations.
1.3 Key Features of the Ideal Logic Combi 35
The Ideal Logic Combi 35 is a high-efficiency combination boiler designed to provide both central heating and instant hot water. Its compact design saves space‚ making it ideal for smaller properties. The boiler features user-friendly controls for easy operation and includes advanced energy-saving technology to reduce fuel bills. With a reliable performance and versatile output options‚ it suits various household needs. The Logic Combi 35 also boasts a high-efficiency rating‚ contributing to lower carbon emissions. Additionally‚ it comes with a comprehensive warranty‚ ensuring long-term peace of mind. These features make it a practical and efficient choice for modern homes seeking a dependable heating solution.
Key Features and Benefits
The Ideal Logic Combi 35 offers high efficiency‚ compact design‚ and user-friendly controls‚ ensuring energy savings and reliable performance for both heating and hot water needs.
2.1 High-Efficiency Combination Boiler
The Ideal Logic Combi 35 is a high-efficiency combination boiler‚ designed to provide both central heating and instant hot water. With outputs of 24kW‚ 30kW‚ and 35kW‚ it ensures reliable performance while minimizing energy consumption. This boiler features advanced condensing technology‚ which captures and reuses heat from flue gases‚ significantly improving efficiency. The result is lower fuel bills and reduced carbon emissions. Its compact design and user-friendly controls make it easy to operate and maintain. The Logic Combi 35 also includes automatic settings and a system pressure gauge for optimal performance. Regular servicing and maintenance are crucial to uphold its efficiency and longevity‚ ensuring it continues to meet your heating and hot water demands effectively.
2.2 Compact Design and Space-Saving
The Ideal Logic Combi 35 boasts a compact design‚ making it ideal for installation in smaller spaces. With dimensions that allow for flexible placement‚ this boiler is perfect for modern homes where space is limited. The unit requires minimal clearance for servicing‚ such as 165mm above‚ 100mm below‚ and 2.5mm at the sides‚ ensuring it fits neatly into most rooms. Its lightweight and streamlined casing further enhance its space-saving capabilities. This design not only simplifies installation but also makes the boiler less obtrusive‚ blending seamlessly into your home environment. The compact build ensures ease of maintenance and accessibility‚ providing a practical solution for efficient heating and hot water delivery without compromising on space.
2.3 User-Friendly Controls
The Ideal Logic Combi 35 features intuitive controls designed for ease of use. The control panel offers straightforward functionality‚ allowing users to adjust central heating and hot water settings with clarity. The interface includes clear indicators for system pressure and operating status‚ making it easy to monitor the boiler’s performance. Additionally‚ the boiler supports compatibility with external timers and smart controls‚ enhancing user convenience. The controls are designed to ensure optimal performance while maintaining simplicity‚ making it accessible for all users to manage their heating and hot water needs efficiently. This user-friendly design simplifies daily operation and troubleshooting‚ ensuring a hassle-free experience.
2.4 Energy Efficiency and Cost Savings
The Ideal Logic Combi 35 is designed to deliver exceptional energy efficiency‚ helping you save on energy bills while reducing carbon emissions. With an A-rated ErP efficiency‚ this boiler ensures optimal performance by converting a high percentage of fuel into usable heat. Its advanced condensing technology minimizes energy waste‚ providing consistent heating and hot water while keeping operational costs low. By maintaining high efficiency‚ the boiler not only reduces your gas bills but also contributes to a more sustainable home. This makes it an eco-friendly and cost-effective solution for modern households seeking reliable and energy-conscious heating systems.
Technical Specifications
The Ideal Logic Combi 35 is a wall-mounted‚ room-sealed‚ condensing combination boiler with outputs of 24kW‚ 30kW‚ and 35kW. It operates on natural gas (G20) at 20mbar‚ featuring a 15mm copper gas connection and varying injector sizes. The boiler is supplied with a 1.8m mains cable for easy installation.
3.1 Boiler Dimensions and Weight
The Ideal Logic Combi 35 boiler is compact and wall-mounted‚ designed to fit seamlessly into small spaces. Its dimensions are optimized for convenience‚ with a depth of 330mm‚ making it ideal for kitchen installations. The boiler weighs approximately 29.5kg‚ ensuring easy handling during installation. Minimum clearances of 165mm above‚ 100mm below‚ and 2.5mm at the sides must be maintained for proper servicing. The front clearance should be at least 450mm to allow easy access. These dimensions ensure the boiler is both space-saving and accessible for maintenance‚ making it a practical choice for modern homes.
3.2 Gas Supply and Compatibility
The Ideal Logic Combi 35 is designed for use with natural gas (G20 ‒ 20mbar) and is compatible with standard gas supply systems. The boiler requires a 15mm copper compression connection for the gas supply. It is essential to ensure the gas supply line is correctly sized and installed to meet the boiler’s specifications. The appliance is not suitable for use with liquefied petroleum gas (LPG) without modification. Always use spare parts approved by Ideal to maintain safety and performance. Proper installation and compatibility with the gas supply are critical for efficient and safe operation of the boiler.
3.3 System Pressure and Safety Features
The Ideal Logic Combi 35 operates with a system pressure gauge‚ indicating the central heating system pressure. The gauge helps monitor pressure levels‚ which should be maintained between 1-2 bar for optimal performance. If the pressure drops below this range‚ it may indicate a water leak. The boiler features built-in safety mechanisms‚ including automatic shutdown in case of low pressure or malfunction. Regular pressure checks and maintenance are essential to ensure safe and efficient operation. Always re-pressurize the system according to the manufacturer’s instructions to prevent damage and maintain boiler reliability. These safety features are designed to protect both the appliance and the user.
Installation Requirements
Ensure minimum clearances of 165mm above‚ 100mm below‚ and 450mm at the front for servicing. Bottom clearance can be reduced to 5mm with a removable panel.
4.1 Minimum Clearances for Servicing
To ensure proper installation and maintenance‚ specific clearances must be maintained around the Ideal Logic Combi 35 boiler. A minimum of 165mm (6.5 inches) of clearance is required above the boiler to allow adequate ventilation and access for servicing. Additionally‚ 100mm (4 inches) of space must be left below the unit‚ and 2.5mm (0.1 inches) on both sides. The front of the boiler must have at least 450mm (17.75 inches) of clearance to facilitate easy access for engineers. These clearances ensure safe operation and compliance with installation standards. Always refer to local building regulations and manufacturer guidelines for precise measurements. Proper spacing prevents overheating and ensures efficient performance. Failure to maintain these clearances may void the warranty or compromise safety. Always use authorized spare parts and follow the manual’s instructions for any adjustments or repairs.
4.2 Bottom Clearance and Accessibility
The Ideal Logic Combi 35 boiler requires specific bottom clearance for proper installation and maintenance. After installation‚ the bottom clearance can be reduced to a minimum of 5mm. However‚ this reduced clearance must be achieved using an easily removable panel to ensure accessibility for servicing. This design allows engineers to maintain and repair the boiler efficiently without compromising safety or performance. Proper bottom clearance prevents obstruction of internal components and ensures adequate airflow‚ which is crucial for optimal operation. Always ensure the boiler is installed by a qualified professional to meet these specifications and maintain compliance with safety standards. Regular checks should be performed to verify that the clearance remains unobstructed and within recommended guidelines. This ensures reliable functionality and extends the boiler’s lifespan. By adhering to these requirements‚ you can ensure safe and efficient operation of your Ideal Logic Combi 35 boiler.
4.3 Gas Supply Connection Details
The Ideal Logic Combi 35 boiler requires a 15mm copper compression connection for the gas supply. The boiler is designed to operate with a gas type of 2H (G20) at a supply pressure of 20mbar. Ensure the gas supply line is correctly sized and installed to meet the boiler’s specifications. The burner and injector sizes are 4.15mm‚ 4.65mm‚ and 4.9mm‚ depending on the model. Proper connection is essential for efficient and safe operation. Always follow the manufacturer’s guidelines and local gas safety regulations. Improper connections can lead to hazards‚ so only qualified professionals should perform the installation. Regular inspections are recommended to ensure the gas supply system remains safe and functional. Adherence to these specifications guarantees optimal performance and compliance with safety standards.
Operating the Boiler
Understand the control panel to set central heating and hot water preferences. Adjust system pressure as needed and follow daily maintenance tips for optimal performance and efficiency.
5.1 Understanding the Control Panel
The control panel on the Ideal Logic Combi 35 features an intuitive interface with a clear LCD display. It allows you to set temperatures‚ timers‚ and system preferences. The panel includes buttons for adjusting central heating and hot water temperatures separately. The display shows current system status‚ error codes‚ and maintenance reminders. Familiarize yourself with the buttons and their functions to optimize boiler performance. Regularly check the display for updates and alerts to ensure smooth operation. Understanding the control panel is key to maximizing efficiency and comfort in your home heating system.
5.2 Setting Up Central Heating and Hot Water
To set up central heating and hot water on your Ideal Logic Combi 35‚ use the control panel to adjust temperatures and settings. Set your desired central heating temperature (typically between 20-22°C) and hot water temperature (ideally 55°C for efficiency). Ensure the system pressure is within the recommended range (1-2 bar) before operation. Use the preheat function for hot water to ensure a constant supply. Programming the timer allows you to schedule heating and hot water according to your daily needs. Regularly check and adjust these settings to optimize energy efficiency and comfort; Always refer to the manual for specific instructions to avoid errors during setup.
5.3 Adjusting System Water Pressure
Adjusting the system water pressure on your Ideal Logic Combi 35 is essential for optimal performance. The system pressure gauge‚ located on the control panel‚ indicates the current pressure. If the pressure drops below the recommended range (1-2 bar)‚ re-pressurize the system by locating the filling loop beneath the boiler. Open the valves slowly until the gauge reaches the desired level. Avoid over-pressurizing‚ as this could damage the system. If you notice consistent pressure drops‚ check for leaks or consult a professional. Always refer to the manual for specific instructions to ensure safety and efficiency during this process.
5.4 Daily Operation and Maintenance Tips
For optimal performance‚ regularly inspect the Ideal Logic Combi 35 boiler and its components. Check for leaks around pipes and connections‚ and ensure the condensate drain is clear. Bleed radiators if necessary to remove airlocks‚ which can reduce heating efficiency. Maintain the system pressure between 1-2 bar‚ as outlined in the manual. Clean the external casing and surrounding area to prevent dust buildup. Schedule annual servicing by a qualified engineer to ensure compliance with safety standards. Keep the user manual handy for quick reference‚ and familiarize yourself with error codes to address issues promptly. Regular maintenance helps extend the boiler’s lifespan and ensures reliable operation.
Maintenance and Servicing
Regular annual servicing by a qualified engineer is essential for the Ideal Logic Combi 35. Check system pressure‚ inspect components‚ and ensure all parts are authorized.
6.1 Routine Checks and Inspections
Regular maintenance is crucial for the Ideal Logic Combi 35. Homeowners should perform routine checks‚ including verifying system pressure between 1-2 bar and inspecting for leaks or damage. Annual servicing by a qualified engineer ensures optimal performance and safety. This includes checking the gas supply‚ burner‚ and heat exchanger. Always use authorized spare parts to maintain efficiency and warranty validity. Clearances around the boiler must be maintained for proper ventilation and easy servicing. Refer to the manual for detailed inspection guidelines to ensure your boiler operates efficiently and safely throughout its lifespan.
6.2 Replacing Spare Parts and Filters
When replacing parts on the Ideal Logic Combi 35‚ only use spare parts authorized by Ideal to ensure safety and performance. Unauthorized or reconditioned parts may void the warranty and compromise efficiency. Regularly inspect and replace filters to maintain airflow and prevent system issues. Refer to the manual for specific instructions on replacing components like the injector or heat exchanger. Always follow the manufacturer’s guidelines for compatibility and installation. Proper replacement ensures optimal boiler performance and longevity. For detailed steps‚ consult the manual or contact a qualified engineer. This maintains the boiler’s efficiency and safety standards over time.
6.3 Annual Servicing Requirements
Annual servicing is essential to maintain the efficiency‚ safety‚ and longevity of the Ideal Logic Combi 35 boiler. A qualified engineer should perform a detailed inspection‚ including checks on the heat exchanger‚ burner‚ and gas supply. The flue and ventilation systems must be inspected to ensure proper operation. Additionally‚ the system pressure should be checked and adjusted if necessary. Cleaning or replacing the filter is also recommended to maintain optimal performance. Always use spare parts authorized by Ideal to ensure compliance with safety standards. Regular servicing not only prevents potential issues but also ensures the boiler operates efficiently‚ saving energy and reducing costs over time. Schedule annual maintenance to keep your boiler in prime condition.
Troubleshooting Common Issues
This section helps identify and resolve common issues with the Ideal Logic Combi 35‚ such as error codes‚ low pressure‚ and leaks‚ ensuring optimal boiler performance.
7.1 Identifying Error Codes
The Ideal Logic Combi 35 boiler displays error codes to indicate specific issues. These codes‚ such as pressure-related errors‚ help diagnose problems quickly. Consult the manual or manufacturer’s guide to understand each code’s meaning. Common issues include low system pressure‚ which may trigger re-pressurization alerts. Error codes guide users or engineers to resolve faults efficiently‚ ensuring the boiler operates safely and effectively. Always refer to the manual for detailed troubleshooting steps and solutions to restore optimal performance. Regular checks can prevent recurring issues‚ maintaining reliability and efficiency.
7.2 Resolving System Pressure Drops
A drop in system pressure is a common issue with combination boilers. If the pressure gauge indicates a drop below the recommended level (usually 1-2 bar)‚ it may signal a leak or system bleed. To resolve this‚ switch off the boiler and allow it to cool. Re-pressurize the system using the filling loop‚ following the manufacturer’s instructions. Ensure the pressure stabilizes at the recommended level. If the pressure drops again‚ inspect for leaks around connections or radiators. Persistent issues may require professional assistance to avoid damage to the boiler or system. Always refer to the manual for detailed guidance on re-pressurization and leak detection.
7.3 Dealing with Leaks and Faults
Leaks and faults in the Ideal Logic Combi 35 boiler can often be identified through error codes or visible water damage. If a leak is detected‚ immediately turn off the boiler and isolate the water supply. Check connections‚ pipes‚ and radiators for signs of damage or corrosion. For minor leaks‚ tighten loose fittings‚ but for major issues‚ contact a Gas Safe registered engineer. The boiler may display error codes like E5 or E6‚ indicating system faults. Refer to the manual for specific code meanings and follow troubleshooting steps. Always prioritize safety and avoid attempting complex repairs without professional assistance to prevent further damage or hazards.
Safety Guidelines
Always follow safety precautions to ensure safe operation. Turn off the boiler in emergencies‚ handle gas leaks promptly‚ and perform regular maintenance checks to prevent hazards.
8.1 General Safety Precautions
Ensure proper ventilation in the room where the boiler is installed to prevent carbon monoxide buildup. Always follow the manufacturer’s instructions for installation and maintenance. Keep the boiler area clear of flammable materials. Avoid tampering with internal components unless you are a qualified technician. If you suspect a gas leak‚ immediately turn off the gas supply and contact a professional. Regularly inspect the boiler for signs of wear or damage. Never operate the boiler if it is malfunctioning. Ensure all safety devices are functioning correctly. Follow the recommended annual servicing schedule to maintain safety and efficiency. Always refer to the manual for specific safety guidelines tailored to your Ideal Logic Combi 35 boiler.
8.2 Emergency Shutdown Procedures
In case of an emergency‚ such as a suspected gas leak or boiler malfunction‚ follow these steps to safely shut down the Ideal Logic Combi 35. First‚ turn off the gas supply at the isolator valve‚ typically located near the boiler. Next‚ switch off the electrical power to the boiler at the mains. Do not attempt to restart the boiler yourself. Contact a qualified Gas Safe engineer immediately to assess and resolve the issue. Ensure all occupants are aware of the situation and take necessary precautions to maintain safety. Always prioritize professional intervention to avoid potential hazards. Keep emergency contact numbers handy for quick access.
8.3 Handling Gas Leaks and Emergencies
If a gas leak is suspected‚ act immediately to ensure safety. Turn off the gas supply at the isolator valve near the boiler and open windows for ventilation. Do not use electrical switches or ignite flames. Contact a Gas Safe registered engineer urgently to inspect and repair the boiler. Never attempt to fix a gas leak yourself. Keep emergency contact numbers handy and ensure all household members are aware of the procedures. Regular maintenance and annual servicing can help prevent such incidents. Always use genuine spare parts to maintain safety and performance. Prioritize professional assistance to resolve gas-related emergencies swiftly and safely.
The Ideal Logic Combi 35 manual provides essential guidance for optimal boiler performance‚ ensuring efficiency‚ safety‚ and reliability. Follow the instructions carefully for years of trouble-free operation.
9.1 Summary of Key Points
The Ideal Logic Combi 35 manual is a detailed guide for installing‚ operating‚ and maintaining this high-efficiency combination boiler. It covers essential features like compact design‚ user-friendly controls‚ and energy efficiency. The boiler is designed to provide central heating and hot water while minimizing energy consumption. Proper installation‚ regular maintenance‚ and adherence to safety guidelines are emphasized to ensure optimal performance. The manual also provides troubleshooting tips and instructions for resolving common issues‚ such as system pressure drops or leaks. By following the guidelines outlined‚ users can enjoy reliable‚ cost-effective‚ and safe heating and hot water solutions for years to come.
9.2 Final Tips for Optimal Boiler Performance
To ensure your Ideal Logic Combi 35 boiler operates at its best‚ regular servicing by a qualified engineer is essential. Always maintain proper system water pressure and address any drops promptly. Check for leaks and ensure all connections are secure. Use only genuine spare parts to maintain safety and efficiency. Keep the area around the boiler clear for proper ventilation and easy access. Follow the manufacturer’s guidelines for energy-saving settings to reduce costs. Schedule annual inspections to prevent issues before they arise. By adhering to these tips‚ you can enjoy consistent heating‚ hot water‚ and long-term reliability from your boiler.